  specification model rps-60-3.3 rps-60-12 rps-60-5 rps-60-15 rps-60-24 rps-60-48 dc voltage rated current current range rated power peak load(10sec.) note.4 output voltage adj. range line regulation load regulation setup, rise time hold up time (typ.) voltage range frequency range efficiency (typ.) ac current (typ.) input inrush current (typ.) leakage current safety standards harmonic current ems immunity working temp. working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing over load over voltage 3.3v 12v 5v 15v 24v 48v 10a 5a 10a 4a 2.5a 1.25a 0 ~ 11a 0 ~ 5.5a 0 ~ 11a 0 ~ 4.4a 0 ~ 2.75a 0 ~ 1.375a 33w 36.3w 60w 66w 50w 55w 60w 66w 60w 66w 60w 66w 80mvp-p 120mvp-p 80mvp-p 150mvp-p 240mvp-p 300mvp-p 3.1 ~ 3.6v 11.4 ~ 13.2v 4.75 ~ 5.5v 13.5 ~ 16.5v 22.8 ~ 27.6v 45.6 ~ 52.8v 2.0% 2.0% 2.0% 0.5% 0.5% 1.0% 1.0% 2.0% 0.5% 1.0% 1.0% 0.5% 1.0% 1.0% 0.5% 1.0% 0.5% 1.0% 500ms, 30ms/230vac 500ms, 30ms/115vac at full load 50ms/230vac 13ms/115vac at full load 90 ~ 264vac 127 ~ 370vdc 47 ~ 63hz 3.8 ~ 5v 5.75 ~ 6.75v 13.8 ~ 16.2v 17.25 ~ 20.25v 28.4 ~ 32.4v 55.2 ~ 64.8v 74% 83% 79% 84% 85% 86% 1.8a/115vac 1 a/230vac cold start 60a/230vac 30a/115vac 115 ~ 150% rated output power compliance to en55011 (cispr11), en55022 (cispr22) class b compliance to en61000-3-2,-3 -20 ~ +70 (refer to output load derating curve) 20 ~ 90% rh non-condensing -40 ~ +85 , 10 ~ 95% rh 0.03%/ (0 ~ 45 ) 10 ~ 500hz, 2g 10min./1cycle, period for 60min. each along x, y, z axes 353.6khrs min. mil-hdbk-217f (25 ) file name:rps-60-spec 2011-03-31 101.6*50.8*29mm (l*w*h) 60w single output medical type r p s - 6 0 s e r i e s withstand voltage isolation resistance i/p-o/p, i/p-fg, o/p-fg:100m ohms / 500vdc/ 25 / 70% rh environment safety & emc (note 5) protection emi conduction & radiation 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. 33% duty cycle maximum within every 30 seconds. average output power sho uld not exceed the rated power. 5. the power supply is considered a component which will be installed into a f inal equipment. the final equipment must be re-confirmed that it still me ets emc directives. 6. length of set up time is measured at cold first start. turning on/off the powe r supply may lead to increase of the set up time. 7. heat sink hs1,hs2 can not be shorted. for guidance on how to perform these emc tests, please refer to ?emi testing of c omponent power supplies.? (as available on http://www.meanwell.com) ripple & noise (max.) note.2 voltage tolerance note.3 features : protection type : hiccup mode, recovers automatically after fault con dition is removed protection type : shut down o/p voltage, re-power on to recover ul60950-1, tuv en60950-1, ul60601-1, tuv en60601-1, iec60601- 1 approved compliance to en61000-4-2,3,4,5,6,8,11; env50204, en55024, e n60601-1-2, en61204-3, medical level, criteria a 4"x2" miniature size universal ac input/full range low leakage current<200ua protections: short circuit / overload / over voltage cooling by free air convection ul60601-1/iec60601-1/en60601-1 medical safety approved no load power consumption<0.75w fixed switch frequency at 100khz 3 years warranty ul60950-1/iec60950-1/en60950-1 ite safety approved for earth <200ua / 264vac, for patient <100ua/264vac i/p-o/p:4kvac i/p-fg:1.5kvac o/p-fg:1.5kvac 0.15kg; 96pcs/15.4kg/0.89cuft en60601-1iec60601-1
mechanical specification unit:mm block diagram circuit detection o.l.p. emi filter rectifiers & filter power switching filter & rectifiers +v -v i/p fg control o.v.p. output derating vs input voltage input voltage (vac) 60hz 90 100 95 120 115 160 140 200 180 240 220 264 load (%) ta=25 90 100 80 70 60 50 40 output derating ambient temperature ( ) load (%) -20 0 20 10 30 40 20 40 80 60 100 60 65 50 70 fosc : 100khz ac input connector (cn1) : jst b3p-vh or equivalent pin no. 12 3 assignment ac/n no pin ac/l mating housing jst vhr jst svh-21t-p1.1 or equivalent or equivalent terminal dc output connector (cn2) : jst b4p-vh or equivalent pin no. 1,2 3,4 assignment +v -v mating housing jst vhr or equivalent terminal jst svh-21t-p1.1 or equivalent file name:rps-60-spec 2011-03-31 r p s - 6 0 s e r i e s 12 3 4 svr1 cn2 4- 3.3 101.6 50.8 44.45 3.175 29 95.25 3.175 cn1 2 3 1 (horizontal) 3 max. fs1 fs2 ac fuse t2.5/250v ac fuse t2.5/250v hs1,hs2 can not be shorted hs1 hs2 60w single output medical type


▲Up To Search▲   

 
Price & Availability of RPS-6011

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X